Physics and conventions

Hamiltonian

The 2D implementation uses

\[ H=-t\sum_{\langle i,j\rangle}(b_i^\dagger b_j+b_j^\dagger b_i) +\frac{U_{2D}}2\sum_i n_i(n_i-1)-\mu\sum_i n_i. \]

The existing 1D implementation uses \(U_{1D}n_i(n_i-1)\) instead. To match interaction strengths, set \(U_{1D}=U_{2D}/2\). Loading a model or changing its device does not convert this physical convention.

The cutoff Nmax is inclusive: \(0\le n_i\le N_{\max}\). Fixed-sector ED and VMC use \(\sum_i n_i=N_{\mathrm{tot}}\). Larger cutoffs and thermodynamic extrapolation are separate physical checks, not consequences of a high finite-system fidelity.

Geometry and indexing

For 2D, physical zero-based site index is i = y*Lx + x. A Julia lattice matrix with shape (Lx, Ly) has this order when flattened with vec(image). A batch of flat configurations has shape (Lx*Ly, walkers) in Julia.

The boundary flags pbc_x and pbc_y are independent. The 2D graph uses unique unordered hopping edges, with no self bonds. A periodic axis of length two has one edge; the historical 1D short-ring convention includes parallel bonds. Use open chains or periodic length at least three for cross-dimension parity tests after converting the interaction coefficient.

Network output and normalization

nn_value and nn_values return unnormalized real log amplitudes. They are neither probabilities nor normalized wavefunctions. For a complete sector,

\[ \log Z=\operatorname{logsumexp}_{\mathbf n}(2f_\theta(\mathbf n)),\qquad P(\mathbf n)=\exp(2f_\theta(\mathbf n)-\log Z). \]

A raw network has no particle-number projection. Inference on configurations outside its training sector is allowed but unconstrained. VMC proposals preserve a chosen particle number; this does not prove the raw network vanishes in other sectors. Never normalize each walker batch independently and treat those values as a globally normalized state.

Symmetry

GroupEquivariantConv2DNet uses a lifting convolution, a group convolution, pointwise SiLU activations and a mean readout over sites and orientations. Its internal features are equivariant and its scalar output is invariant.

On periodic squares, it enforces translations and D4 rotations/reflections. On periodic rectangles, the same D4-tied local filters enforce translations and D2 lattice symmetry. A quarter turn relates transposed shapes, not two states on the same non-square lattice. Both axes must be periodic for this ansatz; other families support their documented boundary choices.

Training objectives: log-MSE and VMC

Changing the training objective does not change the ansatz or its inference API. Both produce the raw log amplitude \(f_\theta\). The distinction is where the training signal comes from:

Workflow Objective Training information Update examples
ED-supervised fitting Normalized log-amplitude MSE Exact small-sector ED state and all configurations in that sector Adam
Energy-based VMC Variational energy Network samples and Hamiltonian matrix elements; no ED state needed Native energy gradient with Adam, or SR with SGD

For a sector \(\mathcal S\), define

\[ \ell_\theta(n)=f_\theta(n)-\tfrac12\operatorname{logsumexp}_{m\in\mathcal S} \bigl(2f_\theta(m)\bigr). \]

Log-MSE minimizes

\[ \mathcal L_{\log\mathrm{MSE}}= \frac1{|\mathcal S|}\sum_{n\in\mathcal S} \bigl(\ell_\theta(n)-\ell_{ED,\epsilon}(n)\bigr)^2. \]

The ED log target is normalized by the same operation. The legacy 1D helper starts from \(\log(|\psi_{ED}|+\epsilon)\); the 2D trainer starts from \(\log\max(|\psi_{ED}|,\epsilon)\). Both default to \(\epsilon=10^{-12}\), but their small-amplitude regularizations are not identical. The 2D trainer retains the raw ED vector for physical overlap/energy diagnostics and rejects zero or mixed-sign components instead of hiding them with an absolute value. The legacy 1D helper takes absolute values and casts targets to float32. A low log-MSE is not itself an energy-convergence certificate.

For VMC,

\[ E_\theta=\mathbb E_{n\sim P_\theta}[E_{\mathrm{loc}}(n)],\qquad E_{\mathrm{loc}}(n)=\sum_m H_{nm}\exp\bigl(f_\theta(m)-f_\theta(n)\bigr), \]

where \(P_\theta(n)\propto\exp(2f_\theta(n))\) within the sampled sector. Native updates use the sampled energy gradient; SR preconditions the update using log-amplitude parameter derivatives. The historical 1D and current 2D SR implementations use different conventions. For \(M\) samples, let \(J_{sk}=\partial_{\theta_k}f_\theta(n_s)\), \(e_s=E_{\mathrm{loc}}(n_s)-\bar E\) and \(J_c=J-\operatorname{mean}_{s}J\). The documented ridge variants solve

\[ \begin{aligned} \text{1D:}\quad &(J^\mathsf TJ+\tau I)\delta=J^\mathsf T e,\\ \text{2D:}\quad &\left(\frac{J_c^\mathsf TJ_c}{M}+\tau I\right)\delta =\frac{J_c^\mathsf T e}{M}. \end{aligned} \]

The 1D matrix is uncentered and unnormalized; the 2D matrix is a sample covariance. Both SR directions above omit the extra factor of two used in the native energy gradient. With SGD the update is \(\theta\leftarrow\theta-\eta\delta\). The 1D diagonal shift is absolute, so its strength relative to the Gram matrix changes with sample count. Do not transfer tau or learning-rate values between dimensions without retuning. The 1D dense solve also lacks the 2D solver's pre-allocation memory guards.

Adam/SGD choose how the update is applied: VMC and Adam are different kinds of choice, not competing objectives. The 2D SR route requires SGD; both guides show SR+SGD examples. The 1D trainer also accepts SR+Adam, which sends the preconditioned direction to Adam as its gradient; this is a different update from SR+SGD. The 2D SR implementation rejects Adam.

An optional ED reference during VMC is a diagnostic and does not turn it into supervised training. VMC avoids an ED target but still needs convergence, mixing and uncertainty checks. The positive-real ansatz used here does not represent an arbitrary signed or complex wavefunction.

Accuracy and uncertainty

The absolute overlap is \(|\langle\psi_{ED}|\psi_\theta\rangle|\); squared fidelity is its square. We label both explicitly. Energy, overlap and variance are separate diagnostics. Local-energy variance or standard deviation is not an error bar on the mean. Conditional block errors assume suitable mixing and stationarity; finite-size measurements do not establish thermodynamic phases.