Julia API¶
using BoseHubbardNQS
1D loading and evaluation¶
load_nn(path::String="data/bose_hubbard_nqs.pt";
arch=nothing, n_sites=nothing, nmax=nothing, hidden_dim=nothing,
map_location="cpu", device=nothing)
nn_value(model, sigma::AbstractVector{<:Integer}; nmax=nothing)
ansatz_log_amplitude(model, sigma::AbstractVector{<:Integer}; nmax=nothing)
nn_values(model, configs::AbstractMatrix{<:Integer}; nmax=nothing, chunk_size=1024)
load_nn returns the existing Python model object. Legacy loading keywords,
CPU defaults and scalar Float64 results remain available. A supplied execution
device controls model placement; map_location retains its deserialization
meaning. The batch method returns a Vector{Float64} with one result per
configuration column. All outputs are raw log amplitudes. The 1D path argument is a String; use
String(path) for a SubString or another string subtype. The 2D loader
accepts AbstractString.
2D loading and evaluation¶
load_nn_2d(path; device=nothing)
nn_value(model2d, sigma::AbstractVector{<:Integer}; nmax=nothing)
ansatz_log_amplitude(model2d, sigma::AbstractVector{<:Integer}; nmax=nothing)
nn_values(model2d, configs::AbstractMatrix{<:Integer}; nmax=nothing, chunk_size=1024)
The loader returns NQS2D, a handle containing the Python model and checkpoint
metadata. It preserves Lx, Ly, occupation cutoff, particle-sector metadata,
both boundary flags, architecture, floating dtype and Hamiltonian conventions.
The familiar scalar and batch functions dispatch on this handle without
changing the existing 1D model type.
The occupation vector has Lx*Ly sites, ordered i=y*Lx+x. Inference does not
project into the saved particle-number sector. A scalar result is Float64;
a batch result is Vector{Float64}. Empty batches return an empty vector.
2D workflows¶
train_vmc_2d(; kwargs...)
train_ed_2d(; kwargs...)
evaluate_2d(; kwargs...)
The workflow wrappers launch the established Python CLIs using the PythonCall
interpreter and return their reports. They isolate backend global state from
Julia. See the workflow examples for the options, physical
settings, output locations and measurement conventions of the underlying tools.
Workflows inherit CLI defaults, including device="auto". Inference loaders
default to CPU. Pass device="cpu" explicitly for CPU-only workflow execution.
Keyword names follow CLI names, replacing hyphens with underscores. Preserve
capitalization for Lx, Ly, Ntot, Nmax and U. For example:
result = train_ed_2d(arch="FCNet", Lx=2, Ly=2, Ntot=4, Nmax=2,
width=4, epochs=2, device="cpu",
output="pythonTest/2D/outputs/julia-example/best.pt")
report = result["report"]
paths = result["paths"]
Reports are Julia dictionaries. Results also contain captured stdout and
stderr and output paths. Julia input/output paths are resolved from the
caller's working directory before entering the subprocess. Python CLI defaults
still resolve under the 2D directory when a path is omitted.
All 2D training and evaluation output paths remain guarded under
pythonTest/2D/. Checkpoints contain inference weights and metadata, not exact
training-resume state. A failed subprocess raises an error with its diagnostics.
Validation and errors¶
Invalid site counts, out-of-range or non-integer occupations, unsupported checkpoint schemas and unavailable explicit CUDA requests are rejected. Use the conventions when comparing dimensions and the batch guide for layout and precision details.